众所周知,储能是解决削峰填谷问题、满足可再生能源需要的关键方式之一、亦是提高发电设备利用率、提升电网整体的运行效率,进而实现需求侧管理、达成双碳目标及能源革命的重要途径。这也是储能在过去几年里一直保持高增长速度的原因-特别是在欧洲、北美、大洋洲等能源供求较为紧张或用电成本较高的区域。
As we all know, electricity energy storage is one of the key methods to solve the problem of power peak cut, and meet the needs of renewable energy. It is also an important way to improve the utilization rate of power generation equipment, improve the overall operating efficiency of the power grid, thereby achieving demand side management, reaching dual carbon goal, and fulfilling the energy revolution. This is also the reason why energy storage has been maintaining a high growth rate in recent years - especially in Europe, North America, Oceania and other regions where quite tight in energy supply or electricity costs are high.

据专业机构统计,2022年全球的储能系统ESS装机量达到约143GWh,相比2021年同比增加了204%!下图为2021年全球储能出货量的地区分布占比。
According to the statistics of professional institutions, the worldwide installed capacity of ESS - Energy Storage Systems reached approximately 143GWh in 2022, YOY increased 204%! The chart below shows the regional distribution of global energy storage shipments in 2021.
与此同时,储能系统设计过程中除了可靠性等其它因素外,系统本身的安全实乃重中之重的根本,也是能对周遭给予安全信赖和保障的综合考量。那么,储能系统中主要的感知与控制器件都有哪些呢?在此,以工商储能系统为例做些分享和探讨。
At the same time, in addition to reliability and other factors in the design process of energy storage system, the safety of the system itself is the most important and fundamental, and also a comprehensive consideration of the ability to give safety trust and protection to the surroundings. Therefore, what kind of crucial sensors and protective components are required in the ESS? Let’s take the industrial and commercial ESS as an example for further discussion.
一、熔断器FUSE
更加庞大的电池组容量设计,可实现储能系统更长的电池放电时间。同时,电池组内的每个电池单元都代表着一个能量源,而系统中任何一个故障或短路都极有可能导致大量的能源倾泻,其伴随的高电压、大电流极易造成人员的巨大伤害,以及储能自身设备和周边财产的损失风险。作为过流保护(或短路保护)的熔断器,在储能系统的电路安全保护中起着至关重要的作用,主要应用于储能系统中的电池模组、电池簇、储能系统整体、交流直流转换逆变器等。
The design of larger battery capacity layout can achieve ESS longer battery discharge time. Meanwhile, each battery cell in the battery pack represents an energy source, and any short circuit or malfunction in the system will probably cause a large amount of energy pour-out, and accompanying high voltage and high current likely to cause huge personnel injury, as well as the risk of assets losses of ESS itself and the surrounding properties.Fuses, for over-current protection (or short circuit protection), playing a very crucial role in the circuit safety protection of ESS, are mainly used in battery modules, battery clusters, whole ESS circuit, AC/DC inverters.
在分布式储能系统或工业集装箱储能中,电池簇由众多电池组构成(电池组由多个电池单体组成),串联连接多列电池簇便构成了整个储能系统。典型的ESS熔断器应用为:分布于电池组和电池簇的熔断器做支流分控,以及在整体柜中熔断器配合做主路护控。
In a distributed ESS or industrial containerized ESS, a battery cluster consists of multiple battery packs (pack consist of multiple battery cells), and connecting multiple rows of battery clusters in series constitutes the entire ESS. A typical application case is that certain quantity of fuses in battery pack for independent sub-branch current control, some in battery cluster for branch control, and one in the overall cabinet for main circuit protection and control.
1.1 电池组BatteryPacks
通常情况下,每个电池组中使用一只熔断器用作独立的支流护控,大致参数如下:
Generally, one fuse in each battery pack for sub-branch protection, key parameters as follows:
*额定电压:DC250V _Rated Voltage
*额定电流:200~450A _Rated Current
*分段能力:DC50kA(10~15ms) _Sectional Capacity
*符合标准:IEC60269, IEC60077, UL248 _Compliance Standards
1.2电池簇列BatteryCluster
每列电池簇中使用一只熔断器用作过流保护,关键参数如下:
One fuse in each battery cluster for over-current protection, key parameters as follows:
*额定电压:DC1500V _Rated Voltage
*额定电流:100~450A _Rated Current
*分段能力:DC 150kA(10~15ms) _Sectional Capacity
*符合标准:IEC60269, UL248 _Compliance Standards
1.3储能系统整体柜ESS Whole System
储能系统主路中使用一只熔断器用作系统整体的安全护控,关键参数如下:
One fuse in whole system for overall protection, key parameters as follows:
*额定电压:DC1500V _Rated Voltage
*额定电流:450~1800A _Rated Current
*分段能力:DC 150kA(10~15ms) _Sectional Capacity
DC 250kA(≤4ms)
*符合标准:IEC60269, UL248 _Compliance Standards
*额定电压:DC1500V _Rated Voltage
*额定电流:3000A _Rated Current
*分段能力:DC 150kA(10ms)
DC 250kA(4ms) _Sectional Capacity
*符合标准:IEC60269 _Compliance Standards
二、电流传感器 CURRENT SENSOR
当储能柜充放电时,电流传感器检测当前通过的电流值,以积分算法计算整个储能柜的电量状态,以此监控和防止过充、过放情况的发生。由于电流值的精度直接关系到SOC(电池剩余电量)的计算精度,传感器的精度越高意味着计算越精确,越能做到储能系统EMS的安全监测和管理。
When the energy storage cabinet is charged and discharged, the current sensor detects the current value passing through, with algorithm to calculate the power status of the entire energy storage cabinet in order to monitor and prevent overcharge and over discharge. The accuracy of the current value is directly related to the calculation accuracy of SOC ( or battery remaining power), the higher accuracy of the sensor means the more accurate the calculation, and the more capable it is to achieve the EMS safety monitoring and management.
*典型型号:CSHV、CSNV _Typical Product Series
*检测原理:霍尔效应Hall _Measurement Principle
*供电电压:5V/12V _Power Supply Voltage
*测量范围:100~1500A _Measurement Range
*精度:±2.0%/±0.5% _Accuracy
*输出:0.5~4.5V/CAN _Output
三、电池泄漏及热失控传感器 BATTERY LEAKAGE DETECTION
在储能系统中,电池由于热失控而造成泄漏所引发的事故是行业最大的风险点。美国NFPA发布了一个专门针对储能系统安全的安装标准“NFPA855”,就储能电池的系统容量和安装距离等方式都做了严格规定,然而相关的火灾事故依旧在全球屡次发生。
In energy storage systems, accidents caused by leakage of batteries due to thermal runaway are the industry's biggest risk points. The NFPA of the United States has issued an installation standard "NFPA 855" specifically for ESS, which strictly regulates the system capacity and installation distance of ESS batteries. However, related fire accidents still occur repeatedly around the world.
当然,电池泄漏风险也是可以通过技术手段加以预防和控制的。以下简要介绍几种电池泄漏检测的途径:However, the risk of battery leakage can also be prevented and controlled through technical means. Let’s see several approaches to leak detection:
3.1锂电池早期泄漏检测 Battery Leakage Detection
譬如,在锂离子储能系统中,当电池进入故障模式的早期,电池会有氢气、一氧化碳、烷类或烯烃类及卤素类等气体溢出;越快越早探测到这些气体,用户就有更多时间采取措施,从而避免灾难性的热失控故障。霍尼韦尔GAS事业部的产品涵盖了上述所有有害气体的检测传感门类,可助客户设计一套有效的早期泄漏检测系统。
For example, in a lithium ion ESS, when the battery at early stage of a failure mode, hydrogen, carbon monoxide, alkanes, alkenes, and halogens may overflow from the battery; The sooner and earlier these gases are detected, the more time users have to take measures to avoid catastrophic thermal runaway failures. Honeywell GAS's products cover all of the above hazardous gas detection and sensing categories, helping customers design an effective early leak detection system.
3.1.1 CO: Ecosure
*一氧化碳检测,全球年出货量百万级。
*CO detection, millions of pieces yearly sold worldwide.
*量程:0~500ppm _Measurement Range
*反应时间:< 30s _Response Time
3.1.2 H2: 4HYT
*用于氢气安全监测10年以上 Hydrogen detection, safe detection proven more than 10 years.
*量程:0~1000ppm _Measurement Range
*反应时间 < 60s _Response Time
3.1.3 O2: 4Oxv
*氧气监测行业销售第一 Oxygen detection, No.1 in the market.
*量程:0~30%VOL _Measurement Range
*反应时间 < 15s _Response Time
3.2 热失控发生报警检测 Thermal Runaway Detection & Alarm
当电池进入故障模式,储能系统舱内的温度、压力会急剧变化,有害气体溢出的同时也将伴有悬浮颗粒物的产生。通过对压力和颗粒物的检测,可以使得系统BMS更加及时、更加综合、更加准确地进行判断,以阻断电池充放电及储能系统的运行并在必要的时候触发消防系统。另一方面,多传感器的融合,同时也可防止系统因单类部件误判“异常”而带来的设备停运损失和检修麻烦。
When the battery enters the failure mode, the temperature and pressure in the ESS cabin will change sharply, and hazardous gas will overflow accompanied by the generation of suspended particles. Through detecting pressure and particulate matter, the system BMS can make more timely, comprehensive, and accurate judgments to stop the operation of battery charging and discharging and terminate ESS operation, and trigger the fire extinguisher system if necessary. Meanwhile, multi-sensor fusion can also prevent equipment downtime losses and maintenance troubles caused by certain type of component’s misjudged "anomalies" in the system.
3.2.1检测介质:绝对压力值 Detection Medium: Absolute Pressure Value
*通讯:LIN,PWM,CAN _Communication
*预警机制:>绝对压力变化量 _Warning Mechanism: >Absolute Pressure Change
>压力变化速率(可设定)>Pressure Change Ratio (Settable)
*工作电压:6~18V _Operating Voltage
*工作电流:<30mA(连续模式Continuous Mode)_Operating Current
<100uA (ECO 2s)
*响应时间:30ms (连续模式Continuous Mode)_Response Time
1s, 2s (ECO)
*工作温度:-40~105℃_Operating Temperature
3.2.2 检测介质:悬浮颗粒物浓度Detection Medium: Suspended Particle Concentration
*通讯:LIN,PWM,CAN _Communication
*预警机制:>5000μg/m³ _Warning Mechanism:
*工作电压:8~16V _Operating Voltage
*工作电流:<30mA(连续模式ContinuousMode)_Operating Current
<500uA(ECO 12s)
*响应时间:1s(连续模式)_Response Time
12s(ECO)
*工作温度:-40~85℃_Operating Temperature
四、温度传感器 TEMPERATURE SENSORS
分布安装于各电池单元或电池包中的温度传感器,实时感知、监控和传输电池的温度数值给储能系统,当温度异常并超过设定上限时,BMS会综合判断其它传感器的传导变化,进而联动执行端及时停止电池的充放电操作。
The temperature sensors distributed and installed in each battery cell or battery pack - senses, monitors, and transmits the temperature value of the battery to ESS in real time. When the temperature is abnormal and exceeds the setting point limit, the BMS will comprehensively judge the conduction changes of other sensors, then trigger executor to timely stop the charging and discharging operations of the battery.
五、储能柜门异常开启检测 ESS DOOR OPENING DETECTION
储能柜属于高能量密度易燃易爆设备,非专业人事进入储能柜可能会导致不可预测的人身伤害及风险。因此,对于储能系统柜门的远程实时及自动监控便显得格外重要,同时也可防止无关人员擅闯储能柜内部进行捣乱和破坏。在储能柜的柜门上安装行程开关,监控柜门的开关状态并在异常时联动警告和驱离。
ESS cabinets are flammable and explosive equipment with high energy density. Entering the cabinets by unprofessional personnel may cause unpredictable injury and risk. Therefore, remote real-time and automatic monitoring of the ESS cabinet door is particularly important, and it can also prevent unauthorized personnel from trespassing inside the cabinet to cause trouble and damage. Install a limit switch on the door of the cabinet, monitor the opening and closing status of the cabinet door, and trigger warning in case of abnormality.
*额定工作电压、电流:110VDC/1A _Rated Voltage/Currentv
*机械寿命:100万次_Mechanical Lifev
*防护等级:IP67 _IP Level
六、继电器及高压直流接触器 RELAYS & CONTACTORS
作为自动调节和转换电路并起着安全保护作用的各类继电器(包括电磁继电器、固态继电器等)和高压直流接触器,也是储能系统中常见的电控制器件。
As automatic control and conversion circuits, various types of relays (Including electromagnetic relays and solid-state relays) and high-voltage DC contactors that play a protection role are also common electrical control components in ESS.
七、MOS及模块 MOSFET & MODULES
主要应用于储能系统中的各类主、从控制模块中的各类MOSFET及模块,包括将交流电转换为直流电的整流桥、应用于开关电源等的FRD快恢复二极管、实现电能转换与控制的IGBT单管及模块等。
MOSFET and modules for various master and slave control modules in ESS, including rectifier bridges that convert AC power to DC power, FRD-fast recovery diodes for switching power supplies, IGBT transistors and modules that achieve power conversion and control.
八、储能连接器 ESS Connectors
用于户外便携式储能、液冷工业储能系统、高压堆叠家用储能系统、高压储能模组、储能BMS主控/从控板、PCS功率转换系统等。
Connectors for outdoor portable power station, liquid cooled industrial ESS, high-pressure stacked-design residential ESS, ESS modules, BMS master/slave control boards, PCS power conversion systems, etc.
*防护等级:IP67/IP69K_Ingress Protectionv
*额定电流:3A/5A/10A/17A/30A..._Rated Currentv
*连接端口:12pin/30pin/40pin..._Physical Interface Connector
【您已阅读完毕 READING FINISHED】
附录:储能行业专业术语-中英文对照 Appendix: ESS Terminology
ESS:储能系统Energy Storage System
BESS:电池储能系统Battery Energy Storage System
BMS:电池管理系统Battery Management System
EMS:能量管理系统/电芯管理系统Energy Management System
PCS:储能变流器Power Conversion System
SOC:电池剩余电量/电池充电状态State of Charge
LIN:低成本串行通讯网络(通讯)Local interconnect Network
PWM:脉冲宽度调制(通讯)Pulse Width Modulation
CAN:串行通信总线(通讯协议)Controller Area Network
IEC:国际电工委员会International Electrical Commission
MOSFET:金属氧化物半导体型场效应管Metal-Oxide-Semiconductor Field-Effect-Transistor
IGBT:绝缘栅双极型晶体管Insulated Gate Bipolar Transistor
版权声明Copyright Notice:
本文部分数据及图片来源于合作伙伴或者公开网络,已在文中注明出处;如有侵权请联系删除。电话:+86-21-57646228
The data and images in this article are sourced from partners of or from public networks, and the source has been indicated accordingly; If there is any infringement, please contact to delete. Tel:+86-21-57646228






沪公网安备31011702889811号
客服1